Go to The Journal of Clinical Investigation
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Journal stats
  • Publication ethics
  • Publication alerts by email
  • Transfers
  • Advertising
  • Job board
  • Contact
  • Physician-Scientist Development
  • Current issue
  • Past issues
  • By specialty
    • COVID-19
    • Cardiology
    • Immunology
    • Metabolism
    • Nephrology
    • Oncology
    • Pulmonology
    • All ...
  • Videos
  • Collections
    • In-Press Preview
    • Resource and Technical Advances
    • Clinical Research and Public Health
    • Research Letters
    • Editorials
    • Perspectives
    • Physician-Scientist Development
    • Reviews
    • Top read articles

  • Current issue
  • Past issues
  • Specialties
  • In-Press Preview
  • Resource and Technical Advances
  • Clinical Research and Public Health
  • Research Letters
  • Editorials
  • Perspectives
  • Physician-Scientist Development
  • Reviews
  • Top read articles
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Journal stats
  • Publication ethics
  • Publication alerts by email
  • Transfers
  • Advertising
  • Job board
  • Contact

Submit a comment

Implementation of a cardiac PET stress program: comparison of outcomes to the preceding SPECT era
Stacey Knight, David B. Min, Viet T. Le, Kent G. Meredith, Ritesh Dhar, Santanu Biswas, Kurt R. Jensen, Steven M. Mason, Jon-David Ethington, Donald L. Lappe, Joseph B. Muhlestein, Jeffrey L. Anderson, Kirk U. Knowlton
Stacey Knight, David B. Min, Viet T. Le, Kent G. Meredith, Ritesh Dhar, Santanu Biswas, Kurt R. Jensen, Steven M. Mason, Jon-David Ethington, Donald L. Lappe, Joseph B. Muhlestein, Jeffrey L. Anderson, Kirk U. Knowlton
View: Text | PDF
Clinical Research and Public Health Cardiology

Implementation of a cardiac PET stress program: comparison of outcomes to the preceding SPECT era

  • Text
  • PDF
Abstract

BACKGROUND. Cardiac positron emission testing (PET) is more accurate than single photon emission computed tomography (SPECT) at identifying coronary artery disease (CAD); however, the 2 modalities have not been thoroughly compared in a real-world setting. We conducted a retrospective analysis of 60-day catheterization outcomes and 1-year major adverse cardiovascular events (MACE) after the transition from a SPECT- to a PET-based myocardial perfusion imaging (MPI) program. METHODS. MPI patients at Intermountain Medical Center from January 2011–December 2012 (the SPECT era, n = 6,777) and January 2014–December 2015 (the PET era, n = 7,817) were studied. Outcomes studied were 60-day coronary angiography, high-grade obstructive CAD, left main/severe 3-vessel disease, revascularization, and 1-year MACE-revascularization (MACE-revasc; death, myocardial infarction [MI], or revascularization >60 days). RESULTS. Patients were 64 ± 13 years old; 54% were male and 90% were of European descent; and 57% represented a screening population (no prior MI, revascularization, or CAD). During the PET era, compared with the SPECT era, a higher percentage of patients underwent coronary angiography (13.2% vs. 9.7%, P < 0.0001), had high-grade obstructive CAD (10.5% vs. 6.9%, P < 0.0001), had left main or severe 3-vessel disease (3.0% vs. 2.3%, P = 0.012), and had coronary revascularization (56.7% vs. 47.1%, P = 0.0001). Similar catheterization outcomes were seen when restricted to the screening population. There was no difference in 1-year MACE-revasc (PET [5.8%] vs. SPECT [5.3%], P = 0.31). CONCLUSIONS. The PET-based MPI program resulted in improved identification of patients with high-grade obstructive CAD, as well as a larger percentage of revascularization, thus resulting in fewer patients undergoing coronary angiography without revascularization. FUNDING. This observational study was funded using internal departmental funds.

Authors

Stacey Knight, David B. Min, Viet T. Le, Kent G. Meredith, Ritesh Dhar, Santanu Biswas, Kurt R. Jensen, Steven M. Mason, Jon-David Ethington, Donald L. Lappe, Joseph B. Muhlestein, Jeffrey L. Anderson, Kirk U. Knowlton

×

Guidelines

The Editorial Board will only consider comments that are deemed relevant and of interest to readers. The Journal will not post data that have not been subjected to peer review; or a comment that is essentially a reiteration of another comment.

  • Comments appear on the Journal’s website and are linked from the original article’s web page.
  • Authors are notified by email if their comments are posted.
  • The Journal reserves the right to edit comments for length and clarity.
  • No appeals will be considered.
  • Comments are not indexed in PubMed.

Specific requirements

  • Maximum length, 400 words
  • Entered as plain text or HTML
  • Author’s name and email address, to be posted with the comment
  • Declaration of all potential conflicts of interest (even if these are not ultimately posted); see the Journal’s conflict-of-interest policy
  • Comments may not include figures
This field is required
This field is required
This field is required
This field is required
This field is required
This field is required

Copyright © 2026 American Society for Clinical Investigation
ISSN 2379-3708

Sign up for email alerts