Go to The Journal of Clinical Investigation
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Journal stats
  • Publication ethics
  • Publication alerts by email
  • Transfers
  • Advertising
  • Job board
  • Contact
  • Physician-Scientist Development
  • Current issue
  • Past issues
  • By specialty
    • COVID-19
    • Cardiology
    • Immunology
    • Metabolism
    • Nephrology
    • Oncology
    • Pulmonology
    • All ...
  • Videos
  • Collections
    • In-Press Preview
    • Resource and Technical Advances
    • Clinical Research and Public Health
    • Research Letters
    • Editorials
    • Perspectives
    • Physician-Scientist Development
    • Reviews
    • Top read articles

  • Current issue
  • Past issues
  • Specialties
  • In-Press Preview
  • Resource and Technical Advances
  • Clinical Research and Public Health
  • Research Letters
  • Editorials
  • Perspectives
  • Physician-Scientist Development
  • Reviews
  • Top read articles
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Journal stats
  • Publication ethics
  • Publication alerts by email
  • Transfers
  • Advertising
  • Job board
  • Contact
Metabolism of PLTP, CETP, and LCAT on multiple HDL sizes using the Orbitrap Fusion Lumos
Sasha A. Singh, Allison B. Andraski, Hideyuki Higashi, Lang Ho Lee, Ashisha Ramsaroop, Frank M. Sacks, Masanori Aikawa
Sasha A. Singh, Allison B. Andraski, Hideyuki Higashi, Lang Ho Lee, Ashisha Ramsaroop, Frank M. Sacks, Masanori Aikawa
View: Text | PDF
Resource and Technical Advance Vascular biology

Metabolism of PLTP, CETP, and LCAT on multiple HDL sizes using the Orbitrap Fusion Lumos

  • Text
  • PDF
Abstract

Recent in vivo tracer studies demonstrated that targeted mass spectrometry (MS) on the Q Exactive Orbitrap could determine the metabolism of HDL proteins 100s-fold less abundant than apolipoprotein A1 (APOA1). In this study, we demonstrate that the Orbitrap Lumos can measure tracer in proteins whose abundances are 1000s-fold less than APOA1, specifically the lipid transfer proteins phospholipid transfer protein (PLTP), cholesterol ester transfer protein (CETP), and lecithin-cholesterol acyl transferase (LCAT). Relative to the Q Exactive, the Lumos improved tracer detection by reducing tracer enrichment compression, thereby providing consistent enrichment data across multiple HDL sizes from 6 participants. We determined by compartmental modeling that PLTP is secreted in medium and large HDL (alpha2, alpha1, and alpha0) and is transferred from medium to larger sizes during circulation from where it is catabolized. CETP is secreted mainly in alpha1 and alpha2 and remains in these sizes during circulation. LCAT is secreted mainly in medium and small HDL (alpha2, alpha3, prebeta). Unlike PLTP and CETP, LCAT’s appearance on HDL is markedly delayed, indicating that LCAT may reside for a time outside of systemic circulation before attaching to HDL in plasma. The determination of these lipid transfer proteins’ unique metabolic structures was possible due to advances in MS technologies.

Authors

Sasha A. Singh, Allison B. Andraski, Hideyuki Higashi, Lang Ho Lee, Ashisha Ramsaroop, Frank M. Sacks, Masanori Aikawa

×

Figure 2

An interinstrument platform comparison of PLTP and CETP tracer enrichment data.

Options: View larger image (or click on image) Download as PowerPoint
An interinstrument platform comparison of PLTP and CETP tracer enrichmen...
(A) PRM scans of the same CETP peptide from the Q Exactive and the Lumos. The relative peak intensities of the fragment ions are conserved between the 2 instruments. The y7 2HM3 (tracer) peak environment is zoomed in. R = 120 K for the Q Exactive and 240 K for the Lumos. (B) Loess regression plots showing that the standard error (gray) of the fitted curves is lower on the Lumos. PLTP data are from alpha1 and CETP from alpha2. Legend: the PRM ions’ m/z values. (C) Box plots depicting the distribution of the enrichment data in B. Each data point is the average enrichment (n = 3 PRM ions’ measurements) per time point. The box plots depict the minimum and maximum values (whiskers), the upper and lower quartiles, and the median. The length of the box represents the interquartile range. The gray lines indicate the relative shift in enrichment value per given time point. Variance was calculated using individual PRM ion enrichment data in B, not the averages.

Copyright © 2026 American Society for Clinical Investigation
ISSN 2379-3708

Sign up for email alerts